Altair OSM Kit Wet

Gas Humidifier

Outdoor Air Quality TCR Tecora

Altair OSM Kit Wet: stability that improves every analysis.

TCR Tecora_Altair OSM Kit Wet_Photo 1
Leaf Leaf

Precision starts with the sample

Sample humidity is a critical parameter for ensuring reliable gas analysis measurements. When the sample has a lower moisture content than the conditions under which the analyzer was calibrated, systematic errors, measurement instability, and variations in analyzer response may occur.

Altair OSM Kit Wet is the system developed by TCR Tecora® for controlling and stabilizing the humidity of the gas sample prior to analysis. Thanks to Nafion™ membrane technology, the system increases the water vapor content in a controlled manner without altering the chemical composition of the gas, ensuring stable operating conditions and greater measurement reliability.

Discover Nafion™ Technology

At the core of Altair OSM Kit Wet is the Nafion™ MH-110 membrane, a technology designed to selectively transfer only water vapor through a highly selective polymer membrane without altering the composition of the gas sample.

The absence of direct contact between the liquid and the gas eliminates the risk of contamination, while the self-regulating design, with no moving parts, ensures high reliability, excellent corrosion resistance, and virtually maintenance-free operation.

Using deionized water as the humidification source, the system can achieve relative humidity levels of up to 98%, providing effective and stable sample conditioning.

TCR Tecora_Altair OSM Kit Wet_Nafion

Installed directly on the sampling line, Altair OSM Kit Wet maintains the desired relative humidity level through an active humidification process and continuous monitoring of temperature and humidity.

Altair OSM Kit Wet_Banner_Caratteristiche e Spec_ENG

Humidity: A Critical Measurement Variable

Analyzer calibration curves are generally generated using dry gases, while real samples are characterized by variable thermohygrometric conditions. This difference introduces a matrix effect, resulting in a systematic deviation between calibration conditions and actual operating conditions.

An excessively dry sample can cause:

  • INSTRUMENT RESPONSE DRIFT
    AND LONGER STABILIZATION TIMES;

  • SIGNAL OSCILLATIONS
    AND LOSS OF MEASUREMENT ACCURACY;

  • REDUCED PERFORMANCE OF ELECTROCHEMICAL AND PID SENSORS.

How does Altair OSM Kit Wet work?

Why choose it

Thanks to active humidity control, Altair OSM Kit Wet ensures stable operating conditions for analyzers, helping to improve measurement accuracy and repeatability.

Continuous monitoring of temperature and relative humidity allows constant verification of the sample conditions, while easy integration into existing sampling lines and compatibility with data acquisition systems make the system suitable for a wide range of gas monitoring and analysis applications.

Altair OSM Kit Wet is suitable for all applications where sample humidity control is essential to ensure accurate and repeatable measurements.

It is particularly suitable for:

  • GAS SAMPLE CALIBRATION AND CONDITIONING;

  • AIR QUALITY AND EMISSION MONITORING;

  • CONTINUOUS ANALYSIS SYSTEMS;

  • LABORATORIES AND INDUSTRIAL APPLICATIONS.

Altair OSM Kit Wet_Mockup_Fronte
Altair OSM Kit Wet - Umidificatore Gas 5
Altair OSM Kit Wet - Umidificatore Gas 6

Technical specifications

MAXIMUM FLOW2l / min
MAXIMUM PERFORMANCE
Dew point increase up to +18 °C with water at room temperature (Tamb. 25 °C, 2 L/min)
SET POINTConfigurable RH set points for: activation, shutdown, and alarm threshold
TEMPERATURE
-10 to +50°C (0.1°C resolution)
RELATIVE HUMIDITY1 to 99% (0.1% resolution)
CONNECTIONSPTFE 6×4 mm

Download the Altair OSM Kit Wet Technical Datasheet now


Need further information? Contact us!